Kevin O'Connor f3a49604f1 stepcompress: Increase check on max count to 10000000
Some motors have very small step distances and they can generate over
a million steps during a homing operation.  Increase the maximum count
to ten million to avoid triggering the internal sanity check.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>