Deploying to gh-pages from @ Klipper3d/klipper@447a88eb08 🚀
This commit is contained in:
@@ -1314,9 +1314,14 @@ the homing and probing procedure. The Klipper code will detect the
|
||||
overshoot and account for it in its calculations. However, it is
|
||||
important that the hardware design is capable of handling overshoot
|
||||
without causing damage to the machine.</p>
|
||||
<p>Should Klipper detect a communication issue between micro-controllers
|
||||
during multi-mcu homing then it will raise a "Communication timeout
|
||||
during homing" error.</p>
|
||||
<p>In order to use this "multi-mcu homing" capability the hardware must
|
||||
have predictably low latency between the host computer and all of the
|
||||
micro-controllers. Typically the round-trip time must be consistently
|
||||
less than 10ms. High latency (even for short periods) is likely to
|
||||
result in homing failures.</p>
|
||||
<p>Should high latency result in a failure (or if some other
|
||||
communication issue is detected) then Klipper will raise a
|
||||
"Communication timeout during homing" error.</p>
|
||||
<p>Note that an axis with multiple steppers (eg, <code>stepper_z</code> and
|
||||
<code>stepper_z1</code>) need to be on the same micro-controller in order to use
|
||||
multi-mcu homing. For example, if an endstop is on a separate
|
||||
|
||||
Binary file not shown.