# Add-on: Climate
|
|
|
|
## Description
|
|
|
|
This add-on enables the use of your panel's relays to act as a thermostat (either cooler or heater)
|
|
using the internal temperature sensor and independent of the network availability.
|
|
|
|
### Attention
|
|
1. The NSPanel is limited to 2A per relay.
|
|
Don't use it for directly power your cooler/heater if exceeding the panel specifications:
|
|
- 150W/110V/Gang, 300W/110V/Total
|
|
- 300W/220V/Gang, 600W/220V/Total
|
|
2. A target temperature must be set on the climate entity in Home Assistant or the page Climate in your panel.
|
|
|
|
> [!NOTE]
|
|
> More details on the [Sonoff NSPanel's page](https://sonoff.tech/product/central-control-panel/nspanel/)
|
|
> and the [product specifications document](https://sonoff.tech/wp-content/uploads/2021/11/%E4%BA%A7%E5%93%81%E5%8F%82%E6%95%B0%E8%A1%A8-NSPanel-20210831.pdf).
|
|
|
|
## Installation
|
|
|
|
You will need to add the reference to `addon_climate_heat`, `addon_climate_cool` or `addon_climate_dual` files on your ESPHome settings in the `package` section
|
|
and after the `remote_package` (base code), as shown below (for `heat` in this example):
|
|
|
|
> [!NOTE]
|
|
> Occasionally, ESPHome updates may result in the `entity_id` of embedded thermostats being appended with `_2`.
|
|
> If you experience this change, refer to this [forum post](https://community.home-assistant.io/t/esphome-devices-all-renamed-with-2-added/388146) on the Home Assistant Forum for guidance.
|
|
|
|
```yaml
|
|
substitutions:
|
|
# Settings - Editable values
|
|
device_name: "YOUR_NSPANEL_NAME"
|
|
friendly_name: "Your panel's friendly name"
|
|
wifi_ssid: !secret wifi_ssid
|
|
wifi_password: !secret wifi_password
|
|
|
|
# Add-on configuration (if needed)
|
|
## Add-on climate
|
|
heater_relay: "1" # Possible values: "1" or "2"
|
|
|
|
# Customization area
|
|
##### My customization - Start #####
|
|
##### My customization - End #####
|
|
|
|
# Basic and optional configurations
|
|
packages:
|
|
remote_package:
|
|
url: https://github.com/Blackymas/NSPanel_HA_Blueprint
|
|
ref: main
|
|
refresh: 300s
|
|
files:
|
|
- nspanel_esphome.yaml # Basic package
|
|
# Optional advanced and add-on configurations
|
|
# - esphome/nspanel_esphome_advanced.yaml
|
|
# - esphome/nspanel_esphome_addon_ble_tracker.yaml
|
|
# - esphome/nspanel_esphome_addon_bluetooth_proxy.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_cool.yaml
|
|
- esphome/nspanel_esphome_addon_climate_heat.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_dual.yaml
|
|
```
|
|
|
|
## Configuration
|
|
|
|
The following keys are available to be used in your `substitutions`:
|
|
|
|
<!-- markdownlint-disable MD013 MD033 -->
|
|
Key|Required|Supported values|Default|Description
|
|
:-|:-:|:-:|:-:|:-
|
|
cooler_relay|Mandatory for *cool* and *dual*|`1` or `2`|`0` (disabled)|Relay used for control the cooler. User `1` for "Relay 1" or `2` for "Relay 2".
|
|
heater_relay|Mandatory for *heat* and *dual*|`1` or `2`|`0` (disabled)|Relay used for control the heater. User `1` for "Relay 1" or `2` for "Relay 2".
|
|
temp_units|Optional|`°C` or `°F`|`°C`|Temperature unit.
|
|
min_off_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the cooling/heating action must be disengaged before it may be engaged.
|
|
min_run_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the cooling/heating action must be engaged before it may be disengaged.
|
|
min_idle_time|Optional|Positive integer representing the number of seconds|`30`|Minimum duration (in seconds) the idle action must be active before calling another climate action.
|
|
target_low|Optional|Number representing a temperature in the selected unit|`18`|The initial lower treshold for the target temperature.
|
|
target_high|Optional|Number representing a temperature in the selected unit|`24`|The initial higher treshold for the target temperature.
|
|
temp_min|Optional|Number representing a temperature in the selected unit|*cool: `15`*<br>*heat: `7`*<br>*dual: `7`* |The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
|
temp_max|Optional|Number representing a temperature in the selected unit|*cool: `45`*<br>*heat: `35`*<br>*dual: `45`* |The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
|
temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.
|
|
cool_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature above the set point) before engaging cooling.
|
|
cool_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (cooling beyond the set point) before disengaging cooling.
|
|
heat_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature below the set point) before engaging heat.
|
|
heat_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (heating beyond the set point) before disengaging heat.
|
|
|
|
<!-- markdownlint-enable MD013 MD033 -->
|
|
|
|
- All values must be delimited with `""`
|
|
- For more details on the keys, please take a look at [ESPHome Base Climate Configurations](https://esphome.io/components/climate/index.html#base-climate-configuration)
|
|
and [ESPHome Climate Thermostat - Additional actions behavior](https://esphome.io/components/climate/thermostat.html#additional-actions-behavior).
|
|
|
|
## Examples
|
|
|
|
### Cooler
|
|
|
|
```yaml
|
|
substitutions:
|
|
# Settings - Editable values
|
|
device_name: "YOUR_NSPANEL_NAME"
|
|
friendly_name: "Your panel's friendly name"
|
|
wifi_ssid: !secret wifi_ssid
|
|
wifi_password: !secret wifi_password
|
|
|
|
# Add-on configuration (if needed)
|
|
## Add-on climate
|
|
cooler_relay: "1" # Possible values: "1" or "2"
|
|
temp_units: "°F" # Temperatures in Fahrenheit
|
|
temp_min: "40" # Min supported temperature is 40°F
|
|
temp_max: "80" # Max supported temperature is 80°F
|
|
temp_step: "1" # Temperature granularity is 1°F
|
|
cool_deadband: "1.2" # Temperature delta before engaging cooling
|
|
cool_overrun: "1.2" # Temperature delta before disengaging cooling
|
|
|
|
# Customization area
|
|
##### My customization - Start #####
|
|
##### My customization - End #####
|
|
|
|
# Basic and optional configurations
|
|
packages:
|
|
remote_package:
|
|
url: https://github.com/Blackymas/NSPanel_HA_Blueprint
|
|
ref: main
|
|
refresh: 300s
|
|
files:
|
|
- nspanel_esphome.yaml # Basic package
|
|
# Optional advanced and add-on configurations
|
|
# - esphome/nspanel_esphome_advanced.yaml
|
|
# - esphome/nspanel_esphome_addon_ble_tracker.yaml
|
|
# - esphome/nspanel_esphome_addon_bluetooth_proxy.yaml
|
|
- esphome/nspanel_esphome_addon_climate_cool.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_heat.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_dual.yaml
|
|
```
|
|
|
|
### Heater
|
|
|
|
```yaml
|
|
substitutions:
|
|
# Settings - Editable values
|
|
device_name: "YOUR_NSPANEL_NAME"
|
|
friendly_name: "Your panel's friendly name"
|
|
wifi_ssid: !secret wifi_ssid
|
|
wifi_password: !secret wifi_password
|
|
|
|
# Add-on configuration (if needed)
|
|
## Add-on climate
|
|
heater_relay: "1" # Possible values: "1" or "2"
|
|
temp_units: "°F" # Temperatures in Fahrenheit
|
|
temp_min: "40" # Min supported temperature is 40°F
|
|
temp_max: "80" # Max supported temperature is 80°F
|
|
temp_step: "1" # Temperature granularity is 1°F
|
|
heat_deadband: "1.2" # Temperature delta before engaging heat
|
|
heat_overrun: "1.2" # Temperature delta before disengaging heat
|
|
|
|
# Customization area
|
|
##### My customization - Start #####
|
|
##### My customization - End #####
|
|
|
|
# Basic and optional configurations
|
|
packages:
|
|
remote_package:
|
|
url: https://github.com/Blackymas/NSPanel_HA_Blueprint
|
|
ref: main
|
|
refresh: 300s
|
|
files:
|
|
- nspanel_esphome.yaml # Basic package
|
|
# Optional advanced and add-on configurations
|
|
# - esphome/nspanel_esphome_advanced.yaml
|
|
# - esphome/nspanel_esphome_addon_ble_tracker.yaml
|
|
# - esphome/nspanel_esphome_addon_bluetooth_proxy.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_cool.yaml
|
|
- esphome/nspanel_esphome_addon_climate_heat.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_dual.yaml
|
|
```
|
|
|
|
|
|
### Dual
|
|
|
|
```yaml
|
|
substitutions:
|
|
# Settings - Editable values
|
|
device_name: "YOUR_NSPANEL_NAME"
|
|
friendly_name: "Your panel's friendly name"
|
|
wifi_ssid: !secret wifi_ssid
|
|
wifi_password: !secret wifi_password
|
|
|
|
# Add-on configuration (if needed)
|
|
## Add-on climate
|
|
heater_relay: "1" # Possible values: "1" or "2"
|
|
cooler_relay: "2" # Possible values: "1" or "2"
|
|
temp_units: "°F" # Temperatures in Fahrenheit
|
|
temp_min: "40" # Min supported temperature is 40°F
|
|
temp_max: "80" # Max supported temperature is 80°F
|
|
temp_step: "1" # Temperature granularity is 1°F
|
|
cool_deadband: "1.2" # Temperature delta before engaging cooling
|
|
cool_overrun: "1.2" # Temperature delta before disengaging cooling
|
|
heat_deadband: "1.2" # Temperature delta before engaging heat
|
|
heat_overrun: "1.2" # Temperature delta before disengaging heat
|
|
|
|
# Customization area
|
|
##### My customization - Start #####
|
|
##### My customization - End #####
|
|
|
|
# Basic and optional configurations
|
|
packages:
|
|
remote_package:
|
|
url: https://github.com/Blackymas/NSPanel_HA_Blueprint
|
|
ref: main
|
|
refresh: 300s
|
|
files:
|
|
- nspanel_esphome.yaml # Basic package
|
|
# Optional advanced and add-on configurations
|
|
# - esphome/nspanel_esphome_advanced.yaml
|
|
# - esphome/nspanel_esphome_addon_ble_tracker.yaml
|
|
# - esphome/nspanel_esphome_addon_bluetooth_proxy.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_cool.yaml
|
|
# - esphome/nspanel_esphome_addon_climate_heat.yaml
|
|
- esphome/nspanel_esphome_addon_climate_dual.yaml
|
|
```
|
|
|
|
### Real Use Case Example: Water Underfloor Heating with NSPanel
|
|
The NSPanel works nicely as a replacement for existing water underfloor heating controllers, installed at eye level and often powered by 100-240VAC.
|
|
In my specific use case, the control valve is of the 'normally closed' type, meaning that an open relay indicates 'no heating.'
|
|
I have utilized relay #1 for this purpose. It's important to note that this setup does not act as a PID controller, but operates on a simple on-off mechanism.
|
|
The system initiates heating at a preset value below and turns it off at a value above the set point.
|
|
I have set these values to `0.1°C` below and `0.1°C` above the target temperature, respectively.
|
|
These adjustments have been effectively maintaining the desired temperature in all of our four rooms.
|
|
The thermostat's settings range from a minimum of `15°C` to a maximum of `22°C`, with a granularity of `0.1°C` for adjustments.
|
|
Furthermore, I have selected `18.3°C` as the default target temperature.
|
|
|
|
```yaml
|
|
##### addon-configuration #####
|
|
## addon_climate ##
|
|
heater_relay: "1" #Use relay 1
|
|
temp_min: "15"
|
|
temp_max: "22"
|
|
temp_step: "0.1"
|
|
cold_tolerance: "0.1"
|
|
hot_tolerance: "0.1"
|
|
|
|
##### CHANGE ME END #####
|
|
climate:
|
|
- id: !extend thermostat_embedded
|
|
visual:
|
|
temperature_step: ${temp_step}
|
|
preset:
|
|
- name: Home
|
|
default_target_temperature_low: 18.3
|
|
mode: "heat"
|
|
```
|
|
|
|
Please note that employing any filter to smooth the temperature readings, such as averaging, is discouraged if the relevant timescale exceeds 1min.
|
|
Such filtering methods can delay the response times of an already slow underfloor heating system.
|
|
Despite this, the temperature stability achieved is quite satisfactory, as illustrated in the graph below.
|
|
|
|

|
|
*On March 24th (around 9:20 PM) and March 25th (around 7:30AM) a window was opened, and all heaters were set to 'off.' for 30min*
|