Add "Model does not match" to manual
This commit is contained in:
Binary file not shown.
Binary file not shown.
Binary file not shown.
@@ -178,7 +178,7 @@ trigger:
|
||||
```
|
||||
|
||||
## Climate control with Relays
|
||||
> Attention!! Although these instructions are still valid, since v4.0 there is a better way to setup a climate control using the panel's relays: https://github.com/Blackymas/NSPanel_HA_Blueprint/wiki/(EN)-Add%E2%80%90on:-Climate
|
||||
> Attention!! Although these instructions are still valid, since v4.0 there is a better way to setup a climate control using the panel's relays an the [add-on climate](addon_climate.md).
|
||||
|
||||
In order to use the NSPanel to control a radiator or underfloor heating, at least one Generic Thermostat must be created in the HA.
|
||||
More information can be found here: https://www.home-assistant.io/integrations/generic_thermostat/
|
||||
|
||||
BIN
docs/pics/eu_reset_button.png
Normal file
BIN
docs/pics/eu_reset_button.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 16 KiB |
BIN
docs/pics/model_does_not_match.jpg
Normal file
BIN
docs/pics/model_does_not_match.jpg
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 140 KiB |
@@ -21,6 +21,24 @@ The "System data ERROR!" message, sometimes displayed upside-down, appears when
|
||||
While it may seem alarming, this message simply indicates that the TFT file on the display is invalid.
|
||||
A successful TFT upload will resolve this issue.
|
||||
|
||||
### Resolving "Model does not match" on Display
|
||||

|
||||
|
||||
This is one more case where the message sounds more alarming than it actually is.
|
||||
Often, a simple reboot of the panel is enough to restore the previous TFT file.
|
||||
This issue typically arises from a corrupt TFT file or server response issues.
|
||||
For troubleshooting, refer to the following sections:
|
||||
- [Using a Local Source (Home Assistant)](#using-a-local-source-home-assistant)
|
||||
- [HTTP Instead of HTTPS](#http-instead-of-https) - Especially important when using the `arduino` framework.
|
||||
- [Check the File Size by Downloading to Your Computer](#check-the-file-size-by-downloading-to-your-computer)
|
||||
|
||||
> [!TIP]
|
||||
> If the TFT transfer has started, your panel might not respond to the reset button on the
|
||||
> device's page in Home Assistant or to holding the hardware button for 15 seconds.
|
||||
> In such cases, you can either power cycle your device using the room's relay on your electrical plate
|
||||
> or use a pin to press the hardware restart button in a small hole behind the device.
|
||||
> 
|
||||
|
||||
### Using the `nspanel_blank.tft` File to Assist
|
||||
|
||||
Many TFT upload problems are associated with the Nextion Active Reparse Mode,
|
||||
@@ -60,7 +78,7 @@ Observe any changes in the display or logs indicators to ensure the device is re
|
||||
|
||||
### HTTP Instead of HTTPS
|
||||
|
||||
- **Issue**: HTTPS connections may be problematic with ESP.
|
||||
- **Issue**: HTTPS connections may be problematic with ESP, especially when using `arduino` as framework.
|
||||
- **Solution**: Use HTTP for hosting the TFT file and updating the `nextion_update_url`.
|
||||
- **Why HTTP?**: HTTP can be more stable for these connections.
|
||||
To switch, simply replace 'https' with 'http' in your URLs and make sure your http server supports non-secure connections.
|
||||
@@ -113,10 +131,16 @@ Compare this with the size listed on GitHub or from the file you downlodaded dir
|
||||
### Power Cycle Your Panel
|
||||
|
||||
- **Issue**: General troubleshooting.
|
||||
- **Solution**: Turn off the power supply, wait a moment, and power it back on.
|
||||
If your panel is already installed in the wall, you probably can still power cycle using your electricity relay's panel and switching the relay connected to your panel.
|
||||
- **How Long to Wait**: Wait at least 30 seconds before turning the power back on.
|
||||
This ensures the system resets to a clean state.
|
||||
- **Solution**: Turn off the power supply, wait for a moment, and then power it back on.
|
||||
If your panel is already installed in the wall, you can often power cycle it by switching the relay connected to your panel in your electricity relay's panel.
|
||||
- **How Long to Wait**: It's recommended to wait at least 30 seconds before turning the power back on.
|
||||
This duration helps ensure that the system resets to a clean state.
|
||||
|
||||
> [!TIP]
|
||||
> If you don't have easy access to your relay's panel, an alternative is to
|
||||
> use a pin to press the hardware restart button, located in a small hole behind the device.
|
||||
> Although this action does not replicate a full power cycle, it might resolve the issue in some cases.
|
||||
> 
|
||||
|
||||
### Flash your panel again
|
||||
|
||||
|
||||
BIN
nspanel_eu.tft
BIN
nspanel_eu.tft
Binary file not shown.
BIN
nspanel_us.tft
BIN
nspanel_us.tft
Binary file not shown.
Binary file not shown.
Reference in New Issue