Expand this to climate cool & dual
This commit is contained in:
@@ -21,6 +21,10 @@ substitutions:
|
||||
temp_step: "0.5"
|
||||
target_low: "18"
|
||||
target_high: "24"
|
||||
cool_deadband: "0.5" # Temperature delta before engaging cooling
|
||||
cool_overrun: "0.5" # Temperature delta before disengaging cooling
|
||||
heat_deadband: "0.5" # Temperature delta before engaging heat
|
||||
heat_overrun: "0.5" # Temperature delta before disengaging heat
|
||||
|
||||
##### DO NOT CHANGE THIS #####
|
||||
addon_climate_cool: "false"
|
||||
|
||||
@@ -74,6 +74,11 @@ target_high|Optional|Number representing a temperature in the selected unit|`24`
|
||||
temp_min|Optional|Number representing a temperature in the selected unit|*cool: `15`*<br>*heat: `7`*<br>*dual: `7`* |The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_max|Optional|Number representing a temperature in the selected unit|*cool: `45`*<br>*heat: `35`*<br>*dual: `45`* |The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.
|
||||
cool_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature above the set point) before engaging cooling.
|
||||
cool_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (cooling beyond the set point) before disengaging cooling.
|
||||
heat_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature below the set point) before engaging heat.
|
||||
heat_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (heating beyond the set point) before disengaging heat.
|
||||
|
||||
<!-- markdownlint-enable MD013 MD033 -->
|
||||
|
||||
- All values must be delimited with `""`
|
||||
@@ -100,6 +105,8 @@ substitutions:
|
||||
temp_min: "40" # Min supported temperature is 40°F
|
||||
temp_max: "80" # Max supported temperature is 80°F
|
||||
temp_step: "1" # Temperature granularity is 1°F
|
||||
cool_deadband: "1.2" # Temperature delta before engaging cooling
|
||||
cool_overrun: "1.2" # Temperature delta before disengaging cooling
|
||||
|
||||
# Customization area
|
||||
##### My customization - Start #####
|
||||
@@ -142,9 +149,8 @@ substitutions:
|
||||
temp_min: "40" # Min supported temperature is 40°F
|
||||
temp_max: "80" # Max supported temperature is 80°F
|
||||
temp_step: "1" # Temperature granularity is 1°F
|
||||
heat_deadband: "0.5" # Temperature delta before engaging heat
|
||||
heat_overrun: "0.5" # Temperature delta before disengaging heat
|
||||
|
||||
heat_deadband: "1.2" # Temperature delta before engaging heat
|
||||
heat_overrun: "1.2" # Temperature delta before disengaging heat
|
||||
|
||||
# Customization area
|
||||
##### My customization - Start #####
|
||||
@@ -188,6 +194,10 @@ substitutions:
|
||||
temp_min: "40" # Min supported temperature is 40°F
|
||||
temp_max: "80" # Max supported temperature is 80°F
|
||||
temp_step: "1" # Temperature granularity is 1°F
|
||||
cool_deadband: "1.2" # Temperature delta before engaging cooling
|
||||
cool_overrun: "1.2" # Temperature delta before disengaging cooling
|
||||
heat_deadband: "1.2" # Temperature delta before engaging heat
|
||||
heat_overrun: "1.2" # Temperature delta before disengaging heat
|
||||
|
||||
# Customization area
|
||||
##### My customization - Start #####
|
||||
|
||||
@@ -19,6 +19,8 @@ climate:
|
||||
- id: !extend thermostat_embedded
|
||||
min_cooling_off_time: ${min_off_time}s
|
||||
min_cooling_run_time: ${min_run_time}s
|
||||
cool_deadband: ${heat_deadband} ${temp_units}
|
||||
cool_overrun: ${heat_overrun} ${temp_units}
|
||||
cool_action:
|
||||
- switch.turn_on: relay_${cooler_relay}
|
||||
preset:
|
||||
|
||||
@@ -18,6 +18,10 @@ climate:
|
||||
min_heating_off_time: ${min_off_time}s
|
||||
min_cooling_run_time: ${min_run_time}s
|
||||
min_heating_run_time: ${min_run_time}s
|
||||
cool_deadband: ${heat_deadband} ${temp_units}
|
||||
cool_overrun: ${heat_overrun} ${temp_units}
|
||||
heat_deadband: ${heat_deadband} ${temp_units}
|
||||
heat_overrun: ${heat_overrun} ${temp_units}
|
||||
cool_action:
|
||||
- switch.turn_on: relay_${cooler_relay}
|
||||
heat_action:
|
||||
|
||||
@@ -10,8 +10,6 @@
|
||||
substitutions:
|
||||
### Local thermostat defaults ###
|
||||
temp_max: "25"
|
||||
heat_deadband: "0.5"
|
||||
heat_overrun: "0.5"
|
||||
|
||||
##### DO NOT CHANGE THIS #####
|
||||
addon_climate_heat: "true"
|
||||
@@ -21,8 +19,8 @@ climate:
|
||||
- id: !extend thermostat_embedded
|
||||
min_heating_off_time: ${min_off_time}s
|
||||
min_heating_run_time: ${min_run_time}s
|
||||
heat_deadband: ${heat_deadband}
|
||||
heat_overrun: ${heat_overrun}
|
||||
heat_deadband: ${heat_deadband} ${temp_units}
|
||||
heat_overrun: ${heat_overrun} ${temp_units}
|
||||
heat_action:
|
||||
- switch.turn_on: relay_${heater_relay}
|
||||
preset:
|
||||
|
||||