@@ -21,6 +21,10 @@ substitutions:
temp_step: "0.5"
target_low: "18"
target_high: "24"
cool_deadband: "0.5" # Temperature delta before engaging cooling
cool_overrun: "0.5" # Temperature delta before disengaging cooling
heat_deadband: "0.5" # Temperature delta before engaging heat
heat_overrun: "0.5" # Temperature delta before disengaging heat
##### DO NOT CHANGE THIS #####
addon_climate_cool: "false"

View File

@@ -74,6 +74,11 @@ target_high|Optional|Number representing a temperature in the selected unit|`24`
temp_min|Optional|Number representing a temperature in the selected unit|*cool: `15`*<br>*heat: `7`*<br>*dual: `7`* |The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
temp_max|Optional|Number representing a temperature in the selected unit|*cool: `45`*<br>*heat: `35`*<br>*dual: `45`* |The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.
cool_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature above the set point) before engaging cooling.
cool_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (cooling beyond the set point) before disengaging cooling.
heat_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature below the set point) before engaging heat.
heat_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (heating beyond the set point) before disengaging heat.
<!-- markdownlint-enable MD013 MD033 -->
- All values must be delimited with `""`
@@ -95,11 +100,13 @@ substitutions:
# Add-on configuration (if needed)
## Add-on climate
cooler_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cooler_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cool_deadband: "1.2" # Temperature delta before engaging cooling
cool_overrun: "1.2" # Temperature delta before disengaging cooling
# Customization area
##### My customization - Start #####
@@ -142,9 +149,8 @@ substitutions:
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
heat_deadband: "0.5" # Temperature delta before engaging heat
heat_overrun: "0.5" # Temperature delta before disengaging heat
heat_deadband: "1.2" # Temperature delta before engaging heat
heat_overrun: "1.2" # Temperature delta before disengaging heat
# Customization area
##### My customization - Start #####
@@ -182,12 +188,16 @@ substitutions:
# Add-on configuration (if needed)
## Add-on climate
heater_relay: "1" # Possible values: "1" or "2"
cooler_relay: "2" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
heater_relay: "1" # Possible values: "1" or "2"
cooler_relay: "2" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cool_deadband: "1.2" # Temperature delta before engaging cooling
cool_overrun: "1.2" # Temperature delta before disengaging cooling
heat_deadband: "1.2" # Temperature delta before engaging heat
heat_overrun: "1.2" # Temperature delta before disengaging heat
# Customization area
##### My customization - Start #####

View File

@@ -19,6 +19,8 @@ climate:
- id: !extend thermostat_embedded
min_cooling_off_time: ${min_off_time}s
min_cooling_run_time: ${min_run_time}s
cool_deadband: ${heat_deadband} ${temp_units}
cool_overrun: ${heat_overrun} ${temp_units}
cool_action:
- switch.turn_on: relay_${cooler_relay}
preset:

View File

@@ -18,6 +18,10 @@ climate:
min_heating_off_time: ${min_off_time}s
min_cooling_run_time: ${min_run_time}s
min_heating_run_time: ${min_run_time}s
cool_deadband: ${heat_deadband} ${temp_units}
cool_overrun: ${heat_overrun} ${temp_units}
heat_deadband: ${heat_deadband} ${temp_units}
heat_overrun: ${heat_overrun} ${temp_units}
cool_action:
- switch.turn_on: relay_${cooler_relay}
heat_action:

View File

@@ -10,8 +10,6 @@
substitutions:
### Local thermostat defaults ###
temp_max: "25"
heat_deadband: "0.5"
heat_overrun: "0.5"
##### DO NOT CHANGE THIS #####
addon_climate_heat: "true"
@@ -21,8 +19,8 @@ climate:
- id: !extend thermostat_embedded
min_heating_off_time: ${min_off_time}s
min_heating_run_time: ${min_run_time}s
heat_deadband: ${heat_deadband}
heat_overrun: ${heat_overrun}
heat_deadband: ${heat_deadband} ${temp_units}
heat_overrun: ${heat_overrun} ${temp_units}
heat_action:
- switch.turn_on: relay_${heater_relay}
preset: