It is possible to have an acceleration greater than max_z_accel on
XY+Z moves. That needs to be taken into account when calculating the
min_stop_interval. This prevents spurious "No next step" MCU errors.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>