axis_twist_compensation: Remove the auto parameter
from axis_twist_compensation Signed-off-by: Jorge Apaza Merma <yochiwarez@gmail.com>
This commit is contained in:
@@ -61,15 +61,6 @@ AXIS_TWIST_COMPENSATION_CALIBRATE AXIS=Y
|
||||
```
|
||||
This will guide you through the same measuring process as for the X-axis.
|
||||
|
||||
### Automatic Calibration for Both Axes
|
||||
To perform automatic calibration for both the X and Y axes without manual
|
||||
intervention, use:
|
||||
```
|
||||
AXIS_TWIST_COMPENSATION_CALIBRATE AUTO=True
|
||||
```
|
||||
In this mode, the calibration process will run for both axes automatically.
|
||||
|
||||
|
||||
> **Tip:** Bed temperature and nozzle temperature and size do not seem to have
|
||||
> an influence to the calibration process.
|
||||
|
||||
|
||||
@@ -154,8 +154,7 @@ The following commands are available when the
|
||||
section](Config_Reference.md#axis_twist_compensation) is enabled.
|
||||
|
||||
#### AXIS_TWIST_COMPENSATION_CALIBRATE
|
||||
`AXIS_TWIST_COMPENSATION_CALIBRATE [AXIS=<X|Y>] [AUTO=<True|False>]
|
||||
[SAMPLE_COUNT=<value>]`
|
||||
`AXIS_TWIST_COMPENSATION_CALIBRATE [AXIS=<X|Y>] [SAMPLE_COUNT=<value>]`
|
||||
|
||||
Calibrates axis twist compensation by specifying the target axis or
|
||||
enabling automatic calibration.
|
||||
@@ -163,11 +162,6 @@ enabling automatic calibration.
|
||||
- **AXIS:** Define the axis (`X` or `Y`) for which the twist compensation
|
||||
will be calibrated. If not specified, the axis defaults to `'X'`.
|
||||
|
||||
- **AUTO:** Enables automatic calibration mode. When `AUTO=True`, the
|
||||
calibration will run for both the X and Y axes. In this mode, `AXIS`
|
||||
cannot be specified. If both `AXIS` and `AUTO` are provided, an error
|
||||
will be raised.
|
||||
|
||||
### [bed_mesh]
|
||||
|
||||