# Configuration checks
|
||||
|
||||
This document provides a list of steps to help confirm the pin
|
||||
settings in the Klipper printer.cfg file. It is a good idea to run
|
||||
through these steps after following the steps in the
|
||||
@@ -10,7 +12,7 @@ in the Octoprint terminal tab and then click "Send"). It's also a good
|
||||
idea to issue a STATUS command after every RESTART to verify that the
|
||||
config file is successfully loaded.
|
||||
|
||||
### Verify temperature
|
||||
## Verify temperature
|
||||
|
||||
Start by verifying that temperatures are being properly reported.
|
||||
Navigate to the Octoprint temperature tab.
|
||||
@@ -22,7 +24,7 @@ present and not increasing. If it is increasing, remove power from the
|
||||
printer. If the temperatures are not accurate, review the
|
||||
"sensor_type" and "sensor_pin" settings for the nozzle and/or bed.
|
||||
|
||||
### Verify M112
|
||||
## Verify M112
|
||||
|
||||
Navigate to the Octoprint terminal tab and issue an M112 command in
|
||||
the terminal box. This command requests Klipper to go into a
|
||||
@@ -37,7 +39,7 @@ The M112 command causes Klipper to go into a "shutdown" state. To
|
||||
clear this state, issue a FIRMWARE_RESTART command in the Octoprint
|
||||
terminal tab.
|
||||
|
||||
### Verify heaters
|
||||
## Verify heaters
|
||||
|
||||
Navigate to the Octoprint temperature tab and type in 50 followed by
|
||||
enter in the "Tool" temperature box. The extruder temperature in the
|
||||
@@ -50,7 +52,7 @@ verify the "heater_pin" setting in the config.
|
||||
If the printer has a heated bed then perform the above test again with
|
||||
the bed.
|
||||
|
||||
### Verify stepper motor enable pin
|
||||
## Verify stepper motor enable pin
|
||||
|
||||
Verify that all of the printer axes can manually move freely (the
|
||||
stepper motors are disabled). If not, issue an M84 command to disable
|
||||
@@ -60,7 +62,7 @@ commodity stepper motor drivers, the motor enable pin is "active low"
|
||||
and therefore the enable pin should have a "!" before the pin (for
|
||||
example, "enable_pin: !ar38").
|
||||
|
||||
### Verify endstops
|
||||
## Verify endstops
|
||||
|
||||
Manually move all the printer axes so that none of them are in contact
|
||||
with an endstop. Send a QUERY_ENDSTOPS command via the Octoprint
|
||||
@@ -81,7 +83,7 @@ require a change to the pullup setting of the pin (the '^' at the
|
||||
start of the endstop_pin name - most printers will use a pullup
|
||||
resistor and the '^' should be present).
|
||||
|
||||
### Verify stepper motors
|
||||
## Verify stepper motors
|
||||
|
||||
Use the STEPPER_BUZZ command to verify the connectivity of each
|
||||
stepper motor. Start by manually positioning the given axis to a
|
||||
@@ -114,7 +116,7 @@ homing mechanism should be tested. Issue a G28 command to home all
|
||||
axes. Remove power from the printer if it does not home properly.
|
||||
Rerun the endstop and stepper motor verification steps if necessary.
|
||||
|
||||
### Verify extruder motor
|
||||
## Verify extruder motor
|
||||
|
||||
To test the extruder motor it will be necessary to heat the extruder
|
||||
to a printing temperature. Navigate to the Octoprint temperature tab
|
||||
@@ -126,7 +128,7 @@ turns in the correct direction. If it does not, see the
|
||||
troubleshooting tips in the previous section to confirm the
|
||||
"enable_pin", "step_pin", and "dir_pin" settings for the extruder.
|
||||
|
||||
### Calibrate PID settings
|
||||
## Calibrate PID settings
|
||||
|
||||
Klipper supports
|
||||
[PID control](https://en.wikipedia.org/wiki/PID_controller) for the
|
||||
@@ -149,7 +151,7 @@ may turn on and off ten times a second, which may not be suitable for
|
||||
heaters using a mechanical switch.) A typical bed PID calibration
|
||||
command is: `PID_CALIBRATE HEATER=heater_bed TARGET=60`
|
||||
|
||||
### Next steps
|
||||
## Next steps
|
||||
|
||||
This guide is intended to help with basic verification of pin settings
|
||||
in the Klipper configuration file. Be sure to read the
|
||||
|
||||