# BL-Touch
|
||||
|
||||
Connecting BL-Touch
|
||||
===================
|
||||
-------------------
|
||||
|
||||
A **warning** before you start: Avoid touching the BL-Touch pin with
|
||||
your bare fingers, since it is quite sensitive to finger grease. And
|
||||
@@ -38,7 +40,7 @@ that the probe doesn't hit anything even if the probe pin happens to
|
||||
be in its lowest state.
|
||||
|
||||
Initial tests
|
||||
=============
|
||||
-------------
|
||||
|
||||
Before moving on, verify that the BL-Touch is mounted at the correct
|
||||
height, the pin should be roughly 2 mm above the nozzle when retracted
|
||||
@@ -82,7 +84,7 @@ If that was successful, do another `G28` (or `PROBE`) but this time
|
||||
let it touch the bed as it should.
|
||||
|
||||
BL-Touch gone bad
|
||||
=================
|
||||
-----------------
|
||||
|
||||
Once the BL-Touch is in inconsistent state, it starts blinking red.
|
||||
You can force it to leave that state by issuing:
|
||||
@@ -105,7 +107,7 @@ light turns on and of. Use the `reset`, `pin_up` and `pin_down`
|
||||
commands to achieve this.
|
||||
|
||||
BL-Touch "clones"
|
||||
=================
|
||||
-----------------
|
||||
|
||||
Many BL-Touch "clone" devices work correctly with Klipper using the
|
||||
default configuration. However, some "clone" devices may require
|
||||
@@ -143,7 +145,7 @@ the second query reports "probe: TRIGGERED" then it indicates that
|
||||
config file.
|
||||
|
||||
BL-Touch v3
|
||||
===========
|
||||
-----------
|
||||
|
||||
Some BL-Touch v3.0 and BL-Touch 3.1 devices may require configuring
|
||||
`probe_with_touch_mode` in the printer config file.
|
||||
@@ -171,7 +173,7 @@ device, be sure to test the probe accuracy before and after setting
|
||||
this value (use the `PROBE_ACCURACY` command to test).
|
||||
|
||||
Multi-probing without stowing
|
||||
=============================
|
||||
-----------------------------
|
||||
|
||||
By default, Klipper will deploy the probe at the start of each probe
|
||||
attempt and then stow the probe afterwards. This repetitive deploying
|
||||
@@ -202,7 +204,7 @@ before and after setting `probe_with_touch_mode` (use the
|
||||
`PROBE_ACCURACY` command to test).
|
||||
|
||||
Calibrating the BL-Touch offsets
|
||||
================================
|
||||
--------------------------------
|
||||
|
||||
Follow the directions in the [Probe Calibrate](Probe_Calibrate.md)
|
||||
guide to set the x_offset, y_offset, and z_offset config parameters.
|
||||
@@ -217,7 +219,7 @@ If an adjustment is made to the probe position, then rerun the probe
|
||||
calibration steps.
|
||||
|
||||
BL-Touch output mode
|
||||
====================
|
||||
--------------------
|
||||
|
||||
* A BL-Touch V3.0 supports setting a 5V or OPEN-DRAIN output mode,
|
||||
a BL-Touch V3.1 supports this too, but can also store this in its
|
||||
|
||||