docs : make modifications to all md files to make them compatible with mkdocs

all markdown files must have a single H1 heading at the top.

Signed-off-by: Damien Martin <damlobster@gmail.com>

Update CNAME
This commit is contained in:
Damien
2021-07-22 00:40:40 +02:00
committed by KevinOConnor
parent 7e88f9220c
commit cff61605fb
44 changed files with 565 additions and 536 deletions

View File

@@ -1,5 +1,7 @@
# BL-Touch
Connecting BL-Touch
===================
-------------------
A **warning** before you start: Avoid touching the BL-Touch pin with
your bare fingers, since it is quite sensitive to finger grease. And
@@ -38,7 +40,7 @@ that the probe doesn't hit anything even if the probe pin happens to
be in its lowest state.
Initial tests
=============
-------------
Before moving on, verify that the BL-Touch is mounted at the correct
height, the pin should be roughly 2 mm above the nozzle when retracted
@@ -82,7 +84,7 @@ If that was successful, do another `G28` (or `PROBE`) but this time
let it touch the bed as it should.
BL-Touch gone bad
=================
-----------------
Once the BL-Touch is in inconsistent state, it starts blinking red.
You can force it to leave that state by issuing:
@@ -105,7 +107,7 @@ light turns on and of. Use the `reset`, `pin_up` and `pin_down`
commands to achieve this.
BL-Touch "clones"
=================
-----------------
Many BL-Touch "clone" devices work correctly with Klipper using the
default configuration. However, some "clone" devices may require
@@ -143,7 +145,7 @@ the second query reports "probe: TRIGGERED" then it indicates that
config file.
BL-Touch v3
===========
-----------
Some BL-Touch v3.0 and BL-Touch 3.1 devices may require configuring
`probe_with_touch_mode` in the printer config file.
@@ -171,7 +173,7 @@ device, be sure to test the probe accuracy before and after setting
this value (use the `PROBE_ACCURACY` command to test).
Multi-probing without stowing
=============================
-----------------------------
By default, Klipper will deploy the probe at the start of each probe
attempt and then stow the probe afterwards. This repetitive deploying
@@ -202,7 +204,7 @@ before and after setting `probe_with_touch_mode` (use the
`PROBE_ACCURACY` command to test).
Calibrating the BL-Touch offsets
================================
--------------------------------
Follow the directions in the [Probe Calibrate](Probe_Calibrate.md)
guide to set the x_offset, y_offset, and z_offset config parameters.
@@ -217,7 +219,7 @@ If an adjustment is made to the probe position, then rerun the probe
calibration steps.
BL-Touch output mode
====================
--------------------
* A BL-Touch V3.0 supports setting a 5V or OPEN-DRAIN output mode,
a BL-Touch V3.1 supports this too, but can also store this in its