It seems the common "beta 3950" thermistors generally follow a temperature table defined by the new "Generic 3950" definition. Using a table that actually follows the "beta 3950" temperature curve is generally less accurate. Deprecate the existing "NTC 100K beta 3950" definition to avoid this common issue. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
@@ -8,6 +8,13 @@ All dates in this document are approximate.
|
||||
|
||||
## Changes
|
||||
|
||||
20211110: The "NTC 100K beta 3950" temperature sensor is deprecated.
|
||||
This sensor will be removed in the near future. Most users will find
|
||||
the "Generic 3950" temperature sensor more accurate. To continue to
|
||||
use the older (typically less accurate) definition, define a custom
|
||||
[thermistor](Config_Reference.md#thermistor) with `temperature1: 25`,
|
||||
`resistance1: 100000`, and `beta: 3950`.
|
||||
|
||||
20211104: The "step pulse duration" option in "make menuconfig" has
|
||||
been removed. A new `step_pulse_duration` setting in the
|
||||
[stepper config section](Config_Reference.md#stepper) should be set
|
||||
|
||||