temperature_sensors: Deprecate "NTC 100K beta 3950" thermistor

It seems the common "beta 3950" thermistors generally follow a
temperature table defined by the new "Generic 3950" definition.  Using
a table that actually follows the "beta 3950" temperature curve is
generally less accurate.  Deprecate the existing "NTC 100K beta 3950"
definition to avoid this common issue.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor
2021-11-01 13:54:11 -04:00
parent 19aac4055d
commit c179db3d43
11 changed files with 20 additions and 11 deletions

View File

@@ -8,6 +8,13 @@ All dates in this document are approximate.
## Changes
20211110: The "NTC 100K beta 3950" temperature sensor is deprecated.
This sensor will be removed in the near future. Most users will find
the "Generic 3950" temperature sensor more accurate. To continue to
use the older (typically less accurate) definition, define a custom
[thermistor](Config_Reference.md#thermistor) with `temperature1: 25`,
`resistance1: 100000`, and `beta: 3950`.