Deploying to gh-pages from @ Klipper3d/klipper@14a83103c3 🚀
This commit is contained in:
@@ -451,8 +451,8 @@
|
||||
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="OctoPrint.md" class="md-nav__link">
|
||||
None
|
||||
<a href="OctoPrint.html" class="md-nav__link">
|
||||
OctoPrint for Klipper
|
||||
</a>
|
||||
</li>
|
||||
|
||||
@@ -1911,6 +1911,33 @@
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#probe_eddy_current" class="md-nav__link">
|
||||
[probe_eddy_current]
|
||||
</a>
|
||||
|
||||
<nav class="md-nav" aria-label="[probe_eddy_current]">
|
||||
<ul class="md-nav__list">
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#probe_eddy_current_calibrate" class="md-nav__link">
|
||||
PROBE_EDDY_CURRENT_CALIBRATE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#ldc_calibrate_drive_current" class="md-nav__link">
|
||||
LDC_CALIBRATE_DRIVE_CURRENT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
@@ -2375,6 +2402,54 @@
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe" class="md-nav__link">
|
||||
[temperature_probe]
|
||||
</a>
|
||||
|
||||
<nav class="md-nav" aria-label="[temperature_probe]">
|
||||
<ul class="md-nav__list">
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_calibrate" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_CALIBRATE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_next" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_NEXT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_complete" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_COMPLETE:
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#abort" class="md-nav__link">
|
||||
ABORT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_enable" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_ENABLE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
@@ -2890,8 +2965,8 @@
|
||||
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="Eddy_Probe.md" class="md-nav__link">
|
||||
None
|
||||
<a href="Eddy_Probe.html" class="md-nav__link">
|
||||
Eddy Current Inductive probe
|
||||
</a>
|
||||
</li>
|
||||
|
||||
@@ -4056,6 +4131,33 @@
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#probe_eddy_current" class="md-nav__link">
|
||||
[probe_eddy_current]
|
||||
</a>
|
||||
|
||||
<nav class="md-nav" aria-label="[probe_eddy_current]">
|
||||
<ul class="md-nav__list">
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#probe_eddy_current_calibrate" class="md-nav__link">
|
||||
PROBE_EDDY_CURRENT_CALIBRATE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#ldc_calibrate_drive_current" class="md-nav__link">
|
||||
LDC_CALIBRATE_DRIVE_CURRENT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
@@ -4520,6 +4622,54 @@
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe" class="md-nav__link">
|
||||
[temperature_probe]
|
||||
</a>
|
||||
|
||||
<nav class="md-nav" aria-label="[temperature_probe]">
|
||||
<ul class="md-nav__list">
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_calibrate" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_CALIBRATE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_next" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_NEXT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_complete" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_COMPLETE:
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#abort" class="md-nav__link">
|
||||
ABORT
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
</nav>
|
||||
|
||||
</li>
|
||||
|
||||
<li class="md-nav__item">
|
||||
<a href="#temperature_probe_enable" class="md-nav__link">
|
||||
TEMPERATURE_PROBE_ENABLE
|
||||
</a>
|
||||
|
||||
</li>
|
||||
|
||||
</ul>
|
||||
@@ -4877,6 +5027,12 @@ section</a> is enabled.</p>
|
||||
<p><code>PROBE_CALIBRATE [SPEED=<speed>] [<probe_parameter>=<value>]</code>:執行一個對校準測頭的z_offset有用的輔助指令碼。有關可選測頭參數的詳細資訊,請參見PROBE命令。參見MANUAL_PROBE命令,瞭解SPEED參數和工具啟用時可用的附加命令的詳細資訊。請注意,PROBE_CALIBRATE命令使用速度變數在XY方向以及Z方向上移動。</p>
|
||||
<h4 id="z_offset_apply_probe">Z_OFFSET_APPLY_PROBE<a class="headerlink" href="#z_offset_apply_probe" title="Permanent link">¶</a></h4>
|
||||
<p><code>Z_OFFSET_APPLY_PROBE</code>:將目前的Z 的 G 程式碼偏移量(就是 babystepping)從 probe 的 z_offset 中減去。該命令將持久化一個常用babystepping 微調值。需要執行 <code>SAVE_CONFIG</code>才能生效。</p>
|
||||
<h3 id="probe_eddy_current">[probe_eddy_current]<a class="headerlink" href="#probe_eddy_current" title="Permanent link">¶</a></h3>
|
||||
<p>The following commands are available when a <a href="Config_Reference.html#probe_eddy_current">probe_eddy_current config section</a> is enabled.</p>
|
||||
<h4 id="probe_eddy_current_calibrate">PROBE_EDDY_CURRENT_CALIBRATE<a class="headerlink" href="#probe_eddy_current_calibrate" title="Permanent link">¶</a></h4>
|
||||
<p><code>PROBE_EDDY_CURRENT_CALIBRATE CHIP=<config_name></code>: This starts a tool that calibrates the sensor resonance frequencies to corresponding Z heights. The tool will take a couple of minutes to complete. After completion, use the SAVE_CONFIG command to store the results in the printer.cfg file.</p>
|
||||
<h4 id="ldc_calibrate_drive_current">LDC_CALIBRATE_DRIVE_CURRENT<a class="headerlink" href="#ldc_calibrate_drive_current" title="Permanent link">¶</a></h4>
|
||||
<p><code>LDC_CALIBRATE_DRIVE_CURRENT CHIP=<config_name></code> This tool will calibrate the ldc1612 DRIVE_CURRENT0 register. Prior to using this tool, move the sensor so that it is near the center of the bed and about 20mm above the bed surface. Run this command to determine an appropriate DRIVE_CURRENT for the sensor. After running this command use the SAVE_CONFIG command to store that new setting in the printer.cfg config file.</p>
|
||||
<h3 id="pwm_cycle_time">[pwm_cycle_time]<a class="headerlink" href="#pwm_cycle_time" title="Permanent link">¶</a></h3>
|
||||
<p>The following command is available when a <a href="Config_Reference.html#pwm_cycle_time">pwm_cycle_time config section</a> is enabled.</p>
|
||||
<h4 id="set_pin_1">SET_PIN<a class="headerlink" href="#set_pin_1" title="Permanent link">¶</a></h4>
|
||||
@@ -5006,6 +5162,18 @@ section</a> is enabled.</p>
|
||||
<p>當啟用 <a href="Config_Reference.html#z_tilt">z_tilt config section</a> 時,以下命令可用。</p>
|
||||
<h4 id="z_tilt_adjust">Z_TILT_ADJUST<a class="headerlink" href="#z_tilt_adjust" title="Permanent link">¶</a></h4>
|
||||
<p><code>Z_TILT_ADJUST [HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]</code>: This command will probe the points specified in the config and then make independent adjustments to each Z stepper to compensate for tilt. See the PROBE command for details on the optional probe parameters. The optional <code>HORIZONTAL_MOVE_Z</code> value overrides the <code>horizontal_move_z</code> option specified in the config file.</p>
|
||||
<h3 id="temperature_probe">[temperature_probe]<a class="headerlink" href="#temperature_probe" title="Permanent link">¶</a></h3>
|
||||
<p>The following commands are available when a <a href="Config_Reference.html#temperature_probe">temperature_probe config section</a> is enabled.</p>
|
||||
<h4 id="temperature_probe_calibrate">TEMPERATURE_PROBE_CALIBRATE<a class="headerlink" href="#temperature_probe_calibrate" title="Permanent link">¶</a></h4>
|
||||
<p><code>TEMPERATURE_PROBE_CALIBRATE [PROBE=<probe name>] [TARGET=<value>] [STEP=<value>]</code>: Initiates probe drift calibration for eddy current based probes. The <code>TARGET</code> is a target temperature for the last sample. When the temperature recorded during a sample exceeds the <code>TARGET</code> calibration will complete. The <code>STEP</code> parameter sets temperature delta (in C) between samples. After a sample has been taken, this delta is used to schedule a call to <code>TEMPERATURE_PROBE_NEXT</code>. The default <code>STEP</code> is 2.</p>
|
||||
<h4 id="temperature_probe_next">TEMPERATURE_PROBE_NEXT<a class="headerlink" href="#temperature_probe_next" title="Permanent link">¶</a></h4>
|
||||
<p><code>TEMPERATURE_PROBE_NEXT</code>: After calibration has started this command is run to take the next sample. It is automatically scheduled to run when the delta specified by <code>STEP</code> has been reached, however its also possible to manually run this command to force a new sample. This command is only available during calibration.</p>
|
||||
<h4 id="temperature_probe_complete">TEMPERATURE_PROBE_COMPLETE:<a class="headerlink" href="#temperature_probe_complete" title="Permanent link">¶</a></h4>
|
||||
<p><code>TEMPERATURE_PROBE_COMPLETE</code>: Can be used to end calibration and save the current result before the <code>TARGET</code> temperature is reached. This command is only available during calibration.</p>
|
||||
<h4 id="abort">ABORT<a class="headerlink" href="#abort" title="Permanent link">¶</a></h4>
|
||||
<p><code>ABORT</code>: Aborts the calibration process, discarding the current results. This command is only available during drift calibration.</p>
|
||||
<h3 id="temperature_probe_enable">TEMPERATURE_PROBE_ENABLE<a class="headerlink" href="#temperature_probe_enable" title="Permanent link">¶</a></h3>
|
||||
<p><code>TEMPERATURE_PROBE_ENABLE ENABLE=[0|1]</code>: Sets temperature drift compensation on or off. If ENABLE is set to 0, drift compensation will be disabled, if set to 1 it is enabled.</p>
|
||||
|
||||
|
||||
</article>
|
||||
|
||||
Reference in New Issue
Block a user