Deploying to gh-pages from @ Klipper3d/klipper@14a83103c3 🚀

This commit is contained in:
KevinOConnor
2024-09-06 00:04:39 +00:00
parent 6478486f2c
commit 6d8124a0cc
303 changed files with 23968 additions and 2228 deletions

View File

@@ -451,8 +451,8 @@
<li class="md-nav__item">
<a href="OctoPrint.md" class="md-nav__link">
None
<a href="OctoPrint.html" class="md-nav__link">
OctoPrint a Klipper-hez
</a>
</li>
@@ -1911,6 +1911,33 @@
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#probe_eddy_current" class="md-nav__link">
[probe_eddy_current]
</a>
<nav class="md-nav" aria-label="[probe_eddy_current]">
<ul class="md-nav__list">
<li class="md-nav__item">
<a href="#probe_eddy_current_calibrate" class="md-nav__link">
PROBE_EDDY_CURRENT_CALIBRATE
</a>
</li>
<li class="md-nav__item">
<a href="#ldc_calibrate_drive_current" class="md-nav__link">
LDC_CALIBRATE_DRIVE_CURRENT
</a>
</li>
</ul>
</nav>
</li>
<li class="md-nav__item">
@@ -2375,6 +2402,54 @@
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#temperature_probe" class="md-nav__link">
[temperature_probe]
</a>
<nav class="md-nav" aria-label="[temperature_probe]">
<ul class="md-nav__list">
<li class="md-nav__item">
<a href="#temperature_probe_calibrate" class="md-nav__link">
TEMPERATURE_PROBE_CALIBRATE
</a>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_next" class="md-nav__link">
TEMPERATURE_PROBE_NEXT
</a>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_complete" class="md-nav__link">
TEMPERATURE_PROBE_COMPLETE:
</a>
</li>
<li class="md-nav__item">
<a href="#abort" class="md-nav__link">
ABORT
</a>
</li>
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_enable" class="md-nav__link">
TEMPERATURE_PROBE_ENABLE
</a>
</li>
</ul>
@@ -2890,8 +2965,8 @@
<li class="md-nav__item">
<a href="Eddy_Probe.md" class="md-nav__link">
None
<a href="Eddy_Probe.html" class="md-nav__link">
Örvényáramú induktív szonda
</a>
</li>
@@ -4056,6 +4131,33 @@
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#probe_eddy_current" class="md-nav__link">
[probe_eddy_current]
</a>
<nav class="md-nav" aria-label="[probe_eddy_current]">
<ul class="md-nav__list">
<li class="md-nav__item">
<a href="#probe_eddy_current_calibrate" class="md-nav__link">
PROBE_EDDY_CURRENT_CALIBRATE
</a>
</li>
<li class="md-nav__item">
<a href="#ldc_calibrate_drive_current" class="md-nav__link">
LDC_CALIBRATE_DRIVE_CURRENT
</a>
</li>
</ul>
</nav>
</li>
<li class="md-nav__item">
@@ -4520,6 +4622,54 @@
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#temperature_probe" class="md-nav__link">
[temperature_probe]
</a>
<nav class="md-nav" aria-label="[temperature_probe]">
<ul class="md-nav__list">
<li class="md-nav__item">
<a href="#temperature_probe_calibrate" class="md-nav__link">
TEMPERATURE_PROBE_CALIBRATE
</a>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_next" class="md-nav__link">
TEMPERATURE_PROBE_NEXT
</a>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_complete" class="md-nav__link">
TEMPERATURE_PROBE_COMPLETE:
</a>
</li>
<li class="md-nav__item">
<a href="#abort" class="md-nav__link">
ABORT
</a>
</li>
</ul>
</nav>
</li>
<li class="md-nav__item">
<a href="#temperature_probe_enable" class="md-nav__link">
TEMPERATURE_PROBE_ENABLE
</a>
</li>
</ul>
@@ -4877,6 +5027,12 @@ section</a> is enabled.</p>
<p><code>PROBE_CALIBRATE [SPEED=&lt;speed&gt;] [&lt;probe_parameter&gt;=&lt;value&gt;]</code>: A szonda z_offset kalibrálásához hasznos segédszkript futtatása. Az opcionális szondaparaméterekkel kapcsolatos részletekért lásd a PROBE parancsot. Lásd a MANUAL_PROBE parancsot a SPEED paraméterre és az eszköz aktív működése közben elérhető további parancsokra vonatkozó részletekért. Felhívjuk a figyelmet, hogy a PROBE_CALIBRATE parancs a sebesség változót használja az XY irányú és a Z irányú mozgáshoz.</p>
<h4 id="z_offset_apply_probe">Z_OFFSET_APPLY_PROBE<a class="headerlink" href="#z_offset_apply_probe" title="Permanent link">&para;</a></h4>
<p><code>Z_OFFSET_APPLY_PROBE</code>: Vegyük az aktuális Z G-kód eltolást (más néven mikrolépés), és vonjuk ki a szonda z_offset-jéből. Ez egy gyakran használt mikrolépés értéket vesz, és "állandóvá teszi". Egy <code>SAVE_CONFIG</code> szükséges a hatálybalépéshez.</p>
<h3 id="probe_eddy_current">[probe_eddy_current]<a class="headerlink" href="#probe_eddy_current" title="Permanent link">&para;</a></h3>
<p>The following commands are available when a <a href="Config_Reference.html#probe_eddy_current">probe_eddy_current config section</a> is enabled.</p>
<h4 id="probe_eddy_current_calibrate">PROBE_EDDY_CURRENT_CALIBRATE<a class="headerlink" href="#probe_eddy_current_calibrate" title="Permanent link">&para;</a></h4>
<p><code>PROBE_EDDY_CURRENT_CALIBRATE CHIP=&lt;config_name&gt;</code>: This starts a tool that calibrates the sensor resonance frequencies to corresponding Z heights. The tool will take a couple of minutes to complete. After completion, use the SAVE_CONFIG command to store the results in the printer.cfg file.</p>
<h4 id="ldc_calibrate_drive_current">LDC_CALIBRATE_DRIVE_CURRENT<a class="headerlink" href="#ldc_calibrate_drive_current" title="Permanent link">&para;</a></h4>
<p><code>LDC_CALIBRATE_DRIVE_CURRENT CHIP=&lt;config_name&gt;</code> This tool will calibrate the ldc1612 DRIVE_CURRENT0 register. Prior to using this tool, move the sensor so that it is near the center of the bed and about 20mm above the bed surface. Run this command to determine an appropriate DRIVE_CURRENT for the sensor. After running this command use the SAVE_CONFIG command to store that new setting in the printer.cfg config file.</p>
<h3 id="pwm_cycle_time">[pwm_cycle_time]<a class="headerlink" href="#pwm_cycle_time" title="Permanent link">&para;</a></h3>
<p>A következő parancs akkor érhető el, ha a <a href="Config_Reference.html#pwm_cycle_time">pwm_cycle_time config section</a> engedélyezve van.</p>
<h4 id="set_pin_1">SET_PIN<a class="headerlink" href="#set_pin_1" title="Permanent link">&para;</a></h4>
@@ -5006,6 +5162,18 @@ section</a> is enabled.</p>
<p>A következő parancsok akkor érhetők el, ha a <a href="Config_Reference.html#z_tilt">z_tilt konfigurációs szakasz</a> engedélyezve van.</p>
<h4 id="z_tilt_adjust">Z_TILT_ADJUST<a class="headerlink" href="#z_tilt_adjust" title="Permanent link">&para;</a></h4>
<p><code>Z_TILT_ADJUST [HORIZONTAL_MOVE_Z=&lt;value&gt;] [&lt;probe_parameter&gt;=&lt;value&gt;]</code>: Ez a parancs a konfigurációban megadott pontokat szondázza, majd független beállításokat végez az egyes Z léptetőkön a dőlés kompenzálása érdekében. Az opcionális szondázó paraméterekkel kapcsolatos részletekért lásd a PROBE parancsot. Az opcionális <code>HORIZONTAL_MOVE_Z</code> érték felülírja a config fájlban megadott <code>horizontal_move_z</code> opciót.</p>
<h3 id="temperature_probe">[temperature_probe]<a class="headerlink" href="#temperature_probe" title="Permanent link">&para;</a></h3>
<p>The following commands are available when a <a href="Config_Reference.html#temperature_probe">temperature_probe config section</a> is enabled.</p>
<h4 id="temperature_probe_calibrate">TEMPERATURE_PROBE_CALIBRATE<a class="headerlink" href="#temperature_probe_calibrate" title="Permanent link">&para;</a></h4>
<p><code>TEMPERATURE_PROBE_CALIBRATE [PROBE=&lt;probe name&gt;] [TARGET=&lt;value&gt;] [STEP=&lt;value&gt;]</code>: Initiates probe drift calibration for eddy current based probes. The <code>TARGET</code> is a target temperature for the last sample. When the temperature recorded during a sample exceeds the <code>TARGET</code> calibration will complete. The <code>STEP</code> parameter sets temperature delta (in C) between samples. After a sample has been taken, this delta is used to schedule a call to <code>TEMPERATURE_PROBE_NEXT</code>. The default <code>STEP</code> is 2.</p>
<h4 id="temperature_probe_next">TEMPERATURE_PROBE_NEXT<a class="headerlink" href="#temperature_probe_next" title="Permanent link">&para;</a></h4>
<p><code>TEMPERATURE_PROBE_NEXT</code>: After calibration has started this command is run to take the next sample. It is automatically scheduled to run when the delta specified by <code>STEP</code> has been reached, however its also possible to manually run this command to force a new sample. This command is only available during calibration.</p>
<h4 id="temperature_probe_complete">TEMPERATURE_PROBE_COMPLETE:<a class="headerlink" href="#temperature_probe_complete" title="Permanent link">&para;</a></h4>
<p><code>TEMPERATURE_PROBE_COMPLETE</code>: Can be used to end calibration and save the current result before the <code>TARGET</code> temperature is reached. This command is only available during calibration.</p>
<h4 id="abort">ABORT<a class="headerlink" href="#abort" title="Permanent link">&para;</a></h4>
<p><code>ABORT</code>: Aborts the calibration process, discarding the current results. This command is only available during drift calibration.</p>
<h3 id="temperature_probe_enable">TEMPERATURE_PROBE_ENABLE<a class="headerlink" href="#temperature_probe_enable" title="Permanent link">&para;</a></h3>
<p><code>TEMPERATURE_PROBE_ENABLE ENABLE=[0|1]</code>: Sets temperature drift compensation on or off. If ENABLE is set to 0, drift compensation will be disabled, if set to 1 it is enabled.</p>
</article>