docs: add initial temperature_probe documentation
Signed-off-by: Eric Callahan <arksine.code@gmail.com>
This commit is contained in:
committed by
KevinOConnor
parent
bd1dbc8af3
commit
6848843224
@@ -2401,6 +2401,65 @@ temperature sensors that are reported via the M105 command.
|
||||
# parameter.
|
||||
```
|
||||
|
||||
### [temperature_probe]
|
||||
|
||||
Reports probe coil temperature. Includes optional thermal drift
|
||||
calibration for eddy current based probes. A `[temperature_probe]`
|
||||
section may be linked to a `[probe_eddy_current]` by using the same
|
||||
postfix for both sections.
|
||||
|
||||
```
|
||||
[temperature_probe my_probe]
|
||||
#sensor_type:
|
||||
#sensor_pin:
|
||||
#min_temp:
|
||||
#max_temp:
|
||||
# Temperature sensor configuration.
|
||||
# See the "extruder" section for the definition of the above
|
||||
# parameters.
|
||||
#smooth_time:
|
||||
# A time value (in seconds) over which temperature measurements will
|
||||
# be smoothed to reduce the impact of measurement noise. The default
|
||||
# is 2.0 seconds.
|
||||
#gcode_id:
|
||||
# See the "heater_generic" section for the definition of this
|
||||
# parameter.
|
||||
#speed:
|
||||
# The travel speed [mm/s] for xy moves during calibration. Default
|
||||
# is the speed defined by the probe.
|
||||
#horizontal_move_z:
|
||||
# The z distance [mm] from the bed at which xy moves will occur
|
||||
# during calibration. Default is 2mm.
|
||||
#resting_z:
|
||||
# The z distance [mm] from the bed at which the tool will rest
|
||||
# to heat the probe coil during calibration. Default is .4mm
|
||||
#calibration_position:
|
||||
# The X, Y, Z position where the tool should be moved when
|
||||
# probe drift calibration initializes. This is the location
|
||||
# where the first manual probe will occur. If omitted, the
|
||||
# default behavior is not to move the tool prior to the first
|
||||
# manual probe.
|
||||
#calibration_bed_temp:
|
||||
# The maximum safe bed temperature (in C) used to heat the probe
|
||||
# during probe drift calibration. When set, the calibration
|
||||
# procedure will turn on the bed after the first sample is
|
||||
# taken. When the calibration procedure is complete the bed
|
||||
# temperature will be set to zero. When omitted the default
|
||||
# behavior is not to set the bed temperature.
|
||||
#calibration_extruder_temp:
|
||||
# The extruder temperature (in C) set probe during drift calibration.
|
||||
# When this option is supplied the procedure will wait for until the
|
||||
# specified temperature is reached before requesting the first manual
|
||||
# probe. When the calibration procedure is complete the extruder
|
||||
# temperature will be set to 0. When omitted the default behavior is
|
||||
# not to set the extruder temperature.
|
||||
#extruder_heating_z: 50.
|
||||
# The Z location where extruder heating will occur if the
|
||||
# "calibration_extruder_temp" option is set. Its recommended to heat
|
||||
# the extruder some distance from the bed to minimize its impact on
|
||||
# the probe coil temperature. The default is 50.
|
||||
```
|
||||
|
||||
## Temperature sensors
|
||||
|
||||
Klipper includes definitions for many types of temperature sensors.
|
||||
|
||||
Reference in New Issue
Block a user