docs: Use hash marks for header lines
Consistently use leading hash marks (#) to note section headers. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
@@ -1,7 +1,6 @@
|
||||
# BL-Touch
|
||||
|
||||
Connecting BL-Touch
|
||||
-------------------
|
||||
## Connecting BL-Touch
|
||||
|
||||
A **warning** before you start: Avoid touching the BL-Touch pin with
|
||||
your bare fingers, since it is quite sensitive to finger grease. And
|
||||
@@ -39,8 +38,7 @@ It's important that the z_hop movement in safe_z_home is high enough
|
||||
that the probe doesn't hit anything even if the probe pin happens to
|
||||
be in its lowest state.
|
||||
|
||||
Initial tests
|
||||
-------------
|
||||
## Initial tests
|
||||
|
||||
Before moving on, verify that the BL-Touch is mounted at the correct
|
||||
height, the pin should be roughly 2 mm above the nozzle when retracted
|
||||
@@ -83,8 +81,7 @@ doesn't stop when you touch the pin.
|
||||
If that was successful, do another `G28` (or `PROBE`) but this time
|
||||
let it touch the bed as it should.
|
||||
|
||||
BL-Touch gone bad
|
||||
-----------------
|
||||
## BL-Touch gone bad
|
||||
|
||||
Once the BL-Touch is in inconsistent state, it starts blinking red.
|
||||
You can force it to leave that state by issuing:
|
||||
@@ -106,8 +103,7 @@ right position so it is able to lower and raise the pin and the red
|
||||
light turns on and of. Use the `reset`, `pin_up` and `pin_down`
|
||||
commands to achieve this.
|
||||
|
||||
BL-Touch "clones"
|
||||
-----------------
|
||||
## BL-Touch "clones"
|
||||
|
||||
Many BL-Touch "clone" devices work correctly with Klipper using the
|
||||
default configuration. However, some "clone" devices may require
|
||||
@@ -144,8 +140,7 @@ the second query reports "probe: TRIGGERED" then it indicates that
|
||||
`pin_up_reports_not_triggered` should be set to False in the Klipper
|
||||
config file.
|
||||
|
||||
BL-Touch v3
|
||||
-----------
|
||||
## BL-Touch v3
|
||||
|
||||
Some BL-Touch v3.0 and BL-Touch 3.1 devices may require configuring
|
||||
`probe_with_touch_mode` in the printer config file.
|
||||
@@ -172,8 +167,7 @@ probe. If configuring this value on a "clone" or older BL-Touch
|
||||
device, be sure to test the probe accuracy before and after setting
|
||||
this value (use the `PROBE_ACCURACY` command to test).
|
||||
|
||||
Multi-probing without stowing
|
||||
-----------------------------
|
||||
## Multi-probing without stowing
|
||||
|
||||
By default, Klipper will deploy the probe at the start of each probe
|
||||
attempt and then stow the probe afterwards. This repetitive deploying
|
||||
@@ -203,8 +197,7 @@ to True. On these devices it is a good idea to test the probe accuracy
|
||||
before and after setting `probe_with_touch_mode` (use the
|
||||
`PROBE_ACCURACY` command to test).
|
||||
|
||||
Calibrating the BL-Touch offsets
|
||||
--------------------------------
|
||||
## Calibrating the BL-Touch offsets
|
||||
|
||||
Follow the directions in the [Probe Calibrate](Probe_Calibrate.md)
|
||||
guide to set the x_offset, y_offset, and z_offset config parameters.
|
||||
@@ -218,8 +211,7 @@ far above the nozzle as possible to avoid it touching printed parts.
|
||||
If an adjustment is made to the probe position, then rerun the probe
|
||||
calibration steps.
|
||||
|
||||
BL-Touch output mode
|
||||
--------------------
|
||||
## BL-Touch output mode
|
||||
|
||||
* A BL-Touch V3.0 supports setting a 5V or OPEN-DRAIN output mode,
|
||||
a BL-Touch V3.1 supports this too, but can also store this in its
|
||||
|
||||
Reference in New Issue
Block a user