smart_effector: Config and command reference

Signed-off-by: Dmitry Butyugin <dmbutyugin@google.com>
This commit is contained in:
Dmitry Butyugin
2021-09-06 02:33:16 +02:00
committed by KevinOConnor
parent 76b22b3125
commit 2060a6908f
2 changed files with 80 additions and 0 deletions

View File

@@ -1746,6 +1746,58 @@ control_pin:
# See the "probe" section for information on these parameters.
```
### [smart_effector]
Smart Effector. One may define this section instead of `[probe]` to enable
the SmartEffector-specific features. This also enables
[runtime commands](G-Codes.md#smart-effector) to adjust the parameters of
the Smart Effector at run time.
```
[smart_effector]
pin:
# Pin connected to the Smart Effector Z Probe output pin (pin 5). Note that
# pullup resistor on the board is generally not required. However, if the
# output pin is connected to the board pin with a pullup resistor, that
# resistor must be high value (e.g. 10K Ohm or more). Some boards have a low
# value pullup resistor on the Z probe input, which will likely result in an
# always-triggered probe state. In this case, connect the Smart Effector to
# a different pin on the board. This parameter is required.
# control_pin:
# Pin connected to the Smart Effector control input pin (pin 7). If provided,
# Smart Effector sensitivity programming commands become available.
# probe_accel:
# If set, limits the acceleration of the probing moves (in mm/sec^2).
# A sudden large acceleration at the beginning of the probing move may
# cause spurious probe triggering, especially if the hotend is heavy.
# To prevent that, it may be necessary to reduce the acceleration of
# the probing moves via this parameter.
# recovery_time: 0.4
# A delay between the travel moves and the probing moves in seconds. A fast
# travel move prior to probing may result in a spurious probe triggering.
# This may cause 'Probe triggered prior to movement' errors if no delay
# is set. Value 0 disables the recovery delay.
# Default value is 0.4.
#x_offset:
#y_offset:
# Should be left unset (or set to 0).
z_offset:
# Trigger height of the probe. Start with -0.1 (mm), and adjust later using
# `PROBE_CALIBRATE` command. This parameter must be provided.
#speed:
# Speed (in mm/s) of the Z axis when probing. It is recommended to start
# with the probing speed of 20 mm/s and adjust it as necessary to improve
# the accuracy and repeatability of the probe triggering.
#samples:
#sample_retract_dist:
#samples_result:
#samples_tolerance:
#samples_tolerance_retries:
#activate_gcode:
#deactivate_gcode:
#deactivate_on_each_sample:
# See the "probe" section for more information on the parameters above.
```
## Additional stepper motors and extruders