docs: Move config reference information to new Config_Reference.md

Move all the config reference information from files in the config/
directory to a new Config_Reference.md document.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor
2020-11-16 18:47:32 -05:00
parent 9fd8f7761e
commit 15b5dbaf8f
120 changed files with 1955 additions and 1378 deletions

View File

@@ -121,8 +121,9 @@ If you want to change the baud rate anyway, then the new rate will
need to be configured in the micro-controller (during **make
menuconfig**) and that updated code will need to be compiled and
flashed to the micro-controller. The Klipper printer.cfg file will
also need to be updated to match that baud rate (see the example.cfg
file for details). For example:
also need to be updated to match that baud rate (see the
[config reference](Config_Reference.md#mcu) for details). For
example:
```
[mcu]
baud: 250000
@@ -149,8 +150,7 @@ when printing directly from OctoPrint. (The printer may move faster
than OctoPrint can send movement commands.) If you wish to run on one
one of these slower boards anyway, consider using the "virtual_sdcard"
feature when printing (see
[config/example-extras.cfg](https://github.com/KevinOConnor/klipper/tree/master/config/example-extras.cfg)
for details).
[config reference](Config_Reference.md#virtual_sdcard) for details).
For running on the Beaglebone, see the
[Beaglebone specific installation instructions](beaglebone.md).
@@ -237,8 +237,7 @@ process itself (or fundamentally does not have a homing process) then
consider using a safe_z_home or homing_override section in the config
file. If you need to move a stepper for diagnostic or debugging
purposes then consider adding a force_move section to the config
file. See
[example-extras.cfg](https://github.com/KevinOConnor/klipper/tree/master/config/example-extras.cfg)
file. See [config reference](Config_Reference.md#customized_homing)
for further details on these options.
### Why is the Z position_endstop set to 0.5 in the default configs?
@@ -341,16 +340,14 @@ See the "config_digital_out" command in the
In addition, the micro-controller software is configured with a
minimum and maximum temperature range for each heater at startup (see
the min_temp and max_temp parameters in the
[example.cfg](https://github.com/KevinOConnor/klipper/tree/master/config/example.cfg)
file for details). If the micro-controller detects that the
temperature is outside of that range then it will also enter a
"shutdown" state.
[config reference](Config_Reference.md#extruder) for details). If the
micro-controller detects that the temperature is outside of that range
then it will also enter a "shutdown" state.
Separately, the host software also implements code to check that
heaters and temperature sensors are functioning correctly. See the
"verify_heater" section of the
[example-extras.cfg](https://github.com/KevinOConnor/klipper/tree/master/config/example-extras.cfg)
for further details.
[config reference](Config_Reference.md#verify_heater) for further
details.
### How do I convert a Marlin pin number to a Klipper pin name?