@@ -2083,7 +2083,7 @@ scan_overshoot: 8
<h3 id="_10">校準<a class="headerlink" href="#_10" title="Permanent link">&para;</a></h3>
<p><code>BED_MESH_CALIBRATE PROFILE=&lt;name&gt; METHOD=[manual | automatic | scan | rapid_scan] \ [&lt;probe_parameter&gt;=&lt;value&gt;] [&lt;mesh_parameter&gt;=&lt;value&gt;] [ADAPTIVE=[0|1] \ [ADAPTIVE_MARGIN=&lt;value&gt;]</code> <em>Default Profile: default</em> <em>Default Method: automatic if a probe is detected, otherwise manual</em> <em>Default Adaptive: 0</em> <em>Default Adaptive Margin: 0</em></p>
<p>啟動床網校準的探測程式。</p>
<p>The mesh will be saved into a profile specified by the <code>PROFILE</code> parameter, or <code>default</code> if unspecified. The <code>METHOD</code> parameter takes one of the following values:</p>
<p>The mesh will be immediately ready to use when the command completes and saved into a profile specified by the <code>PROFILE</code> parameter, or <code>default</code> if unspecified. The <code>METHOD</code> parameter takes one of the following values:</p>
<ul>
<li><code>METHOD=manual</code>: enables manual probing using the nozzle and the paper test</li>
<li><code>METHOD=automatic</code>: Automatic (standard) probing. This is the default.</li>
@@ -2123,6 +2123,7 @@ scan_overshoot: 8
<p>任何其他儲存的配置也可以用相同的方式刪除,用你想刪除的配置名稱替換<em>default</em></p>
<h4 id="loading-the-default-profile">Loading the default profile<a class="headerlink" href="#loading-the-default-profile" title="Permanent link">&para;</a></h4>
<p>Previous versions of <code>bed_mesh</code> always loaded the profile named <em>default</em> on startup if it was present. This behavior has been removed in favor of allowing the user to determine when a profile is loaded. If a user wishes to load the <code>default</code> profile it is recommended to add <code>BED_MESH_PROFILE LOAD=default</code> to either their <code>START_PRINT</code> macro or their slicer's "Start G-Code" configuration, whichever is applicable.</p>
<p>Note that this is not required if a new mesh is generated with <code>BED_MESH_CALIBRATE</code> in the <code>START_PRINT</code> macro or the slicer's "Start G-Code" and may produce unexpected results, especially with adaptive meshing.</p>
<p>Alternatively the old behavior of loading a profile at startup can be restored with a <code>[delayed_gcode]</code>:</p>
<div class="highlight"><pre><span></span><code><span class="k">[delayed_gcode bed_mesh_init]</span>
<span class="na">initial_duration</span><span class="o">:</span><span class="w"> </span><span class="s">.01</span>