@@ -74,6 +74,11 @@ target_high|Optional|Number representing a temperature in the selected unit|`24`
temp_min|Optional|Number representing a temperature in the selected unit|*cool: `15`*<br>*heat: `7`*<br>*dual: `7`* |The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
temp_max|Optional|Number representing a temperature in the selected unit|*cool: `45`*<br>*heat: `35`*<br>*dual: `45`* |The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.
cool_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature above the set point) before engaging cooling.
cool_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (cooling beyond the set point) before disengaging cooling.
heat_deadband|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (temperature below the set point) before engaging heat.
heat_overrun|Optional|Number representing a temperature hysteresis in the selected unit|`0.5`|The minimum temperature differential (heating beyond the set point) before disengaging heat.
<!-- markdownlint-enable MD013 MD033 -->
- All values must be delimited with `""`
@@ -95,11 +100,13 @@ substitutions:
# Add-on configuration (if needed)
## Add-on climate
cooler_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cooler_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cool_deadband: "1.2" # Temperature delta before engaging cooling
cool_overrun: "1.2" # Temperature delta before disengaging cooling
# Customization area
##### My customization - Start #####
@@ -137,11 +144,13 @@ substitutions:
# Add-on configuration (if needed)
## Add-on climate
heater_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
heater_relay: "1" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
heat_deadband: "1.2" # Temperature delta before engaging heat
heat_overrun: "1.2" # Temperature delta before disengaging heat
# Customization area
##### My customization - Start #####
@@ -179,12 +188,16 @@ substitutions:
# Add-on configuration (if needed)
## Add-on climate
heater_relay: "1" # Possible values: "1" or "2"
cooler_relay: "2" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
heater_relay: "1" # Possible values: "1" or "2"
cooler_relay: "2" # Possible values: "1" or "2"
temp_units: "°F" # Temperatures in Fahrenheit
temp_min: "40" # Min supported temperature is 40°F
temp_max: "80" # Max supported temperature is 80°F
temp_step: "1" # Temperature granularity is 1°F
cool_deadband: "1.2" # Temperature delta before engaging cooling
cool_overrun: "1.2" # Temperature delta before disengaging cooling
heat_deadband: "1.2" # Temperature delta before engaging heat
heat_overrun: "1.2" # Temperature delta before disengaging heat
# Customization area