Simplify climate substitutions
This commit is contained in:
@@ -24,7 +24,7 @@ substitutions:
|
||||
|
||||
##### addon-configuration #####
|
||||
## addon_climate ##
|
||||
addon_climate_heater_relay: "1" # possible values: 1/2
|
||||
heater_relay: "1" # possible values: 1/2
|
||||
|
||||
##### CHANGE ME END #####
|
||||
|
||||
@@ -35,7 +35,7 @@ packages:
|
||||
ref: main
|
||||
files:
|
||||
- nspanel_esphome.yaml # Core package
|
||||
- nspanel_esphome_addon_climate.yaml # activate for local climate-control
|
||||
- nspanel_esphome_addon_climate_heat.yaml # activate for local climate (heater) control
|
||||
refresh: 300s
|
||||
```
|
||||
|
||||
@@ -45,14 +45,14 @@ The following keys are available to be used in your `substitutions`:
|
||||
|
||||
|Key|Required|Supported values|Default|Description|
|
||||
|:-|:-:|:-:|:-:|:-|
|
||||
|addon_climate_heater_relay|Mandatory|`1` or `2`|`0` (disabled)|Relay used for conrol the heater. User `1` for "Relay 1" or `2` for "Relay 2".|
|
||||
|addon_climate_temp_units|Optional|`°C` or `°F`|`°C`|Temperature unit.|
|
||||
|addon_climate_min_heating_off_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the heating action must be disengaged before it may be engaged.|
|
||||
|addon_climate_min_heating_run_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the heating action must be engaged before it may be disengaged.|
|
||||
|addon_climate_min_idle_time|Optional|Positive integer representing the number of seconds|`30`|Minimum duration (in seconds) the idle action must be active before calling another climate action.|
|
||||
|addon_climate_visual_min_temperature|Optional|Number representing a temperature in the selected unit|`5`|The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.|
|
||||
|addon_climate_visual_max_temperature|Optional|Number representing a temperature in the selected unit|`25`|The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.|
|
||||
|addon_climate_visual_temperature_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.|
|
||||
|heater_relay|Mandatory|`1` or `2`|`0` (disabled)|Relay used for control the heater. User `1` for "Relay 1" or `2` for "Relay 2".|
|
||||
|temp_units|Optional|`°C` or `°F`|`°C`|Temperature unit.|
|
||||
|min_off_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the heating action must be disengaged before it may be engaged.|
|
||||
|min_run_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the heating action must be engaged before it may be disengaged.|
|
||||
|min_idle_time|Optional|Positive integer representing the number of seconds|`30`|Minimum duration (in seconds) the idle action must be active before calling another climate action.|
|
||||
|temp_min|Optional|Number representing a temperature in the selected unit|`5`|The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.|
|
||||
|temp_max|Optional|Number representing a temperature in the selected unit|`25`|The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.|
|
||||
|temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.|
|
||||
|
||||
- All values must be delimited with `""`
|
||||
- For more details on the keys, please take a look at [ESPHome Base Climate Configurations](https://esphome.io/components/climate/index.html#base-climate-configuration) and [ESPHome Climate Thermostat - Additional actions behavior](https://esphome.io/components/climate/thermostat.html#additional-actions-behavior).
|
||||
@@ -72,11 +72,11 @@ substitutions:
|
||||
|
||||
##### addon-configuration #####
|
||||
## addon_climate ##
|
||||
addon_climate_heater_relay: "1" #Use relay 1
|
||||
addon_climate_temp_units: "°F" #Temperatures in Fahrenheit
|
||||
addon_climate_visual_min_temperature: "40" #Min supported temperature is 40F
|
||||
addon_climate_visual_max_temperature: "80" #Max supported temperature is 80F
|
||||
addon_climate_visual_temperature_step: "1" #Temperature granularity is 1F
|
||||
heater_relay: "1" #Use relay 1
|
||||
temp_units: "°F" #Temperatures in Fahrenheit
|
||||
temp_min: "40" #Min supported temperature is 40°F
|
||||
temp_max: "80" #Max supported temperature is 80°F
|
||||
temp_step: "1" #Temperature granularity is 1°F
|
||||
|
||||
##### CHANGE ME END #####
|
||||
|
||||
@@ -87,7 +87,7 @@ packages:
|
||||
ref: main
|
||||
files:
|
||||
- nspanel_esphome.yaml # Core package
|
||||
- nspanel_esphome_addon_climate.yaml # activate for local climate-control
|
||||
- nspanel_esphome_addon_climate_heat.yaml # activate for local climate (heater) control
|
||||
refresh: 300s
|
||||
```
|
||||
|
||||
|
||||
Reference in New Issue