@@ -19,7 +19,7 @@ Don't use it for directly power your cooler/heater if exceeding the panel specif
## Installation
You will need to add the reference to `addon_climate_heat`, `addon_climate_cool` or `addon_climate_dual` files on your ESPHome settings in the `package` section
and after the `remote_package` (base code), as shown bellow (for `heat` in this example):
and after the `remote_package` (base code), as shown below (for `heat` in this example):
> [!NOTE]
> Occasionally, ESPHome updates may result in the `entity_id` of embedded thermostats being appended with `_2`.
@@ -210,7 +210,7 @@ packages:
### Real Use Case Example: Water Underfloor Heating with NSPanel
The NSPanel works nicely as a replacement for existing water underfloor heating controllers, installed at eye level and often powered by 100-240VAC.
In my specific use case, the control valve is of the 'normally closed' type, meaning that an open relay indicates 'no heating.'
I have utilized relay #1 for this purpose. It's important to note that this setup does not act as a PID controller but operates on a simple on-off mechanism.
I have utilized relay #1 for this purpose. It's important to note that this setup does not act as a PID controller, but operates on a simple on-off mechanism.
The system initiates heating at a preset value below and turns it off at a value above the set point.
I have set these values to `0.1°C` below and `0.1°C` above the target temperature, respectively.
These adjustments have been effectively maintaining the desired temperature in all of our four rooms.