Fix default_target_temperature
It also updates the page home when thermostat status changes (for the chips). Solves https://github.com/Blackymas/NSPanel_HA_Blueprint/discussions/995#discussioncomment-6897727
This commit is contained in:
@@ -56,8 +56,8 @@ temp_units|Optional|`°C` or `°F`|`°C`|Temperature unit.
|
||||
min_off_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the cooling/heating action must be disengaged before it may be engaged.
|
||||
min_run_time|Optional|Positive integer representing the number of seconds|`300`|Minimum duration (in seconds) the cooling/heating action must be engaged before it may be disengaged.
|
||||
min_idle_time|Optional|Positive integer representing the number of seconds|`30`|Minimum duration (in seconds) the idle action must be active before calling another climate action.
|
||||
temp_min|Optional|Number representing a temperature in the selected unit|`5`|The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_max|Optional|Number representing a temperature in the selected unit|`25`|The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_min|Optional|Number representing a temperature in the selected unit|`15` for `cool`, `5` for `heat`|The minimum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_max|Optional|Number representing a temperature in the selected unit|`45` for `cool`, `25` for `heat`|The maximum temperature the climate device can reach. Used to set the range of the frontend gauge.
|
||||
temp_step|Optional|Number representing a temperature in the selected unit|`0.5`|The granularity with which the target temperature can be controlled.
|
||||
|
||||
- All values must be delimited with `""`
|
||||
|
||||