fix button picture fallback
when localfallback is enabled, and the switch is turned off relay_1-> state = off(false) so the action won't be applied and it takes a second for the HA automation to update the icon. so this check should not be here, it should only for fallback and then choose 1/0 based on the state. remark(I cannot test off to on atm as my custom change then opens the detail page, but I have no reason to think this won't work)
This commit is contained in:
@@ -1742,8 +1742,8 @@ script:
|
|||||||
if (relay_2->state) disp1->set_component_text_printf("home.icon_top_02", "%s", id(home_relay2_icon).c_str());
|
if (relay_2->state) disp1->set_component_text_printf("home.icon_top_02", "%s", id(home_relay2_icon).c_str());
|
||||||
else disp1->set_component_text_printf("home.icon_top_02", "\uFFFF");
|
else disp1->set_component_text_printf("home.icon_top_02", "\uFFFF");
|
||||||
// Hardware buttons - Fallback mode
|
// Hardware buttons - Fallback mode
|
||||||
if (relay_1->state and relay1_local->state) disp1->send_command_printf("home.left_bt_pic.val=%i", (relay_1->state) ? 1 : 0);
|
if (relay1_local->state) disp1->send_command_printf("home.left_bt_pic.val=%i", (relay_1->state) ? 1 : 0);
|
||||||
if (relay_2->state and relay2_local->state) disp1->send_command_printf("home.right_bt_pic.val=%i", (relay_2->state) ? 1 : 0);
|
if (relay2_local->state) disp1->send_command_printf("home.right_bt_pic.val=%i", (relay_2->state) ? 1 : 0);
|
||||||
|
|
||||||
- id: refresh_wifi_icon
|
- id: refresh_wifi_icon
|
||||||
mode: restart
|
mode: restart
|
||||||
|
|||||||
Reference in New Issue